Mean Temperature Difference Correction Factor for the TEMA "H" Shell

Get access (open in a dialog) DOI: 10.1615/IHTC8.1140
pages 2709-2714

摘要

A closed analytical expression for calculating the TEMA "H" shell F-factors (mean temperature difference correction factor) is derived. The F-factor, computed for various values of NTU (number of transfer units), and the parameter R (heat capacity rate ratio), are found to be almost identical to the values of TEMA "G" shell F-factor over most of the parameter ranges. The difference becomes significant only when NTU is greater than 20 and R is greater than 4. Therefore, this work confirms for the first time that, for all practical purposes, the TEMA "G" shell F-factor can be substituted for the TEMA "H" shell F-factor. This derivation completes the set of analytical expressions for F-factors of all the TEMA shell types.